Tweezer Electrodes
In Vivo Electroporation Electrodes
- Tweezer w/Variable Gap Electrodes
- It is able to use for In Vivo EP such as embryo, brain, muscle, organ, and many of other targets.
- There are various sizes of electrodes for each application. Please send an inquiry about the suitable electrodes for your experiment.
APPLICATIONS
Electroporation
- Zygotes In Oviduct (i-GONAD method)
- Ex Utero Embryos In Vitro
- Brain
- Retina / Cornea / Spinal Cord / Sciatic Nerve
- Lung / Spleen / Liver / Stomach/ Kidney / Intestine
- Pancreas / Islets of langerhans
- Testis / Ovary / Prostate / Gonad / Uterus
- Muscle / Skin / Joint / Cartilage / Tumor / Others
PRODUCT DESCRIPTION
CUY646P Tweezers w/Variable Gap, 2 Arched Platinum Electrode CUY647P2X2 Tweezers w/Variable Gap, 2 Round Platinum Plate Electrode, 2X2 mm CUY647-15X10 Tweezers w/Variable Gap, 2 Rectangle Electrode, 15mm x 10mm | CUY650-5 Tweezers w/Variable Gap, 2 Round SS Plate Electrode, 5mm diameter CUY650-7 Tweezers w/Variable Gap, 2 Round SS Plate Electrode, 7mm diameter CUY650-10 Tweezers w/Variable Gap, 2 Round SS Plate Electrode, 10mm diameter |
CUY650P0.5 Tweezers w/Variable Gap, 2 Round Platinum Plate Electrode, 0.5mm diameter CUY650P1 Tweezers w/Variable Gap, 2 Round Platinum Plate Electrode, 1mm diameter | CUY650P3 Tweezers w/Variable Gap, 2 Round Platinum Plate Electrode, 3mm diameter CUY650P5 Tweezers w/Variable Gap, 2 Round Platinum Plate Electrode, 5mm diameter |
CUY650P7 Tweezers w/Variable Gap, 2 Round Platinum Plate Electrode, 7mm diameter CUY650P10 Tweezers w/Variable Gap, 2 Round Platinum Plate Electrode, 10mm diameter | CUY650P0.5-3 Tweezers w/Variable Gap, 2 Round Platinum Plate Electrode, 0.5mm & 3mm diameter CUY650P1-5 Tweezers w/Variable Gap, 2 Round Platinum Plate Electrode, 1mm & 5mm diameter |
CUY652P2.5X4 Tweezers w/Variable Gap Concave, Platinum Electrodes, 2.5mm x 4mm CUY652P3X4.5 Tweezers w/Variable Gap Concave, Platinum Electrodes, 3mm x 4.5mm |
CUY654-10 Tweezers w/Variable Gap, 2 Round SS Plate Electrode with Projection, 10mm diameter CUY654-15X10 Tweezers w/Variable Gap, 2 Oval SS Plate Electrode with Projection, 15mm x 10mm | CUY611-3X7 Tweezers w/Variable Gap Tungsten Needle & Oval SS Plate Electrode, 7mm-Tip, 3mm x 7mm CUY661N Replacement Tungsten Needle Electrode for CUY661, 5/pkg. |
CUY663-5X8 Tweezers w/Variable Gap 3 Needle Fork & SS Rectangle Plate Electrode, 5mm x 8mm CUY663-5X10 Tweezers w/Variable Gap 3 Needle Fork & SS Rectangle Plate Electrode, 5mm x 10mm | CUY671P1 Parallel Fixed Platinum Electrode, 1mm Gap, 45 Degree 1mm Exposed, 0.5mm diameter CUY675P5 Tweezers w/Variable Gap, 2 Round Platinum Plate Electrode for Eyes, 5mm diameter |